Plant Physiol. Illumina
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Plant Physiology 85:1059-1062 (1987)
© 1987 American Society of Plant Biologists

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Web of Science (5)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tarczynski, M. C.
Right arrow Articles by Outlaw, W. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tarczynski, M. C.
Right arrow Articles by Outlaw, W. H., Jr.
Agricola
Right arrow Articles by Tarczynski, M. C.
Right arrow Articles by Outlaw, W. H.
Metabolism and Enzymology

Histochemical Technique: Densitometry of Nanogram Quantities of Proteins Separated in One-Dimensional Microslab Gels 1

Mitchell C. Tarczynski and William H. Outlaw, Jr.

Department of Biological Science, Unit I, Florida State University, Tallahassee, Florida 32306-3050

We describe methods for densitometry of electrophoretically separated proteins in 25-millimeter microslab gels. The methods are sufficiently sensitive to use with several individually excised plant cells, for which we describe an extraction procedure. In brief, submicrogram samples are excised from freeze-dried plant tissue. Extraction takes place under oil in microliter droplets of detergent. Proteins are separated by one-dimensional microelectrophoresis (HM Poehling, V Neuhoff 1980 Electrophoresis 1: 90-102) and then stained by a sensitive Coomassie procedure (V Neuhoff, R Stamm, E Hansjorg 1985 Electrophoresis 6: 427-448). The resulting profile is scanned by a computerized densitometer based on the Leitz Diavert MPV Microphotometer. Evaluations and typical data demonstrate the high performance of this system.


1 Supported by a grant from the United States Department of Energy (to W. H. O.).







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ASPB Publications PLANT PHYSIOLOGY® THE PLANT CELL
Copyright © 1987 by the American Society of Plant Biologists